GENERAL BOATING WATERSPORTS & BOATS SEATING COVERS/TOPS MAINTENANCE ELECTRICAL HARDWARE PLUMBING PROPS & ANODES FUEL ELECTRONICS & NAVIGATION SAFETY TROLLING & FISHING ANCHORING/ MOORING TRAILERING PAINT VENTILATION FASTENERS STEERING ENGINE ITEMS ARE STOCKED IN OUR WAREHOUSES BASED ON REGIONAL DEMAND. IF AN ITEM IS NOT IN STOCK AT A LOCAL WAREHOUSE, ADDITIONAL CHARGES MAY APPLY. 726 SECTION ELECTRICAL Item# Description Terminals List 661-5045 4 Circuit w/Cover #8-32 54.59 EA 661-5046 8 Circuit w/Cover #8-32 86.49 EA Provides surface mount circuit protection for ATO®/ATC® Fuses in a compact footprint. The single side design allows wire entry from one side to maximize space. • Common source fuse block • Ignition Protected • Insulating cover meets ABYC/USCG requirements • Tin-plated copper connections • Small format labels available • Fuses sold separately Specifications: • Voltage Max.: 32V DC • Amperage Max.: 30A per circuit • Amperage Max.: 100A per block ST BLADE COMPACT FUSE BLOCK - COMMON SOURCE 5045 5046 Item# Amps Fuse List 661-5035 30A ATO or ATC 74.99 EA Compact ATO®/ATC® fuse block consolidates branch circuits and eliminates the tangle of in-line fuses. Includes a clear insulating cover with label recesses. Uses Blue Sea small format labels and offers storage for one fuse, satisfies ABYC/USCG insulation requirements. Independent circuits allow some 24-hour and some switched circuits in the same block. Tin-plated copper buses and fuse clips. 32 Volts maximum. ST BLADE FUSE BLOCK WITH INDEPENDENT CIRCUITS Item# Description List 661-5032 12 circuits 133.99 EA Two isolated 6-circuit fuse blocks with a negative bus. For use when a mix of switched and 24-hour circuits are desired in the same block. • Common and/or independent source fuse block • For use with either two isolated batteries or with a single battery • Clear insulating cover satisfies ABYC/USCG requirements • Easy to open, push button latch • Tin-plated copper buses and fuse clips • Includes 20 write-on circuit labels • Fuses sold separately Specifications • Voltage Max.: 32V DC • Amperage Max.: 30A per circuit 100A total • Fuse Type: ATO® or ATC® • Screw Terminal: #8-32 Screws ST BLADE SPLIT BUS FUSE BLOCK Used on systems up to 32V. Insulating cover with breakout sides allows AWG cable access in any direction. Insert molded 5/ 16" stainless steel studs provide corrosion resistance and allow high torque. MEGA OR AMG FUSE BLOCK SYSTEM Item# Amps Fuse Size List 661-5001 100-300A Mega 4.07" x 1.5" 44.29 EA Item# Amps Fuse Stud Size List 661-5005 35-300A ANL 5/ 16" - 18 (M8) 4.5'' x 1.5'' 49.99 EA 661-5503 35-750A ANL 5/ 16" - 18 (M8) 7.0'' x 2.0'' 98.49 EA Accepts wide range of ANL Fuse amperages for a versatile ignition protected fusing system. Tin-plated copper bus and stainless steel hardware. A 5/ 16" (M8) stud terminals. Insulation cover with breakouts allow cable access from all directions. Maximum rating: 32 Volts DC. ANL FUSE BLOCK 5005 5503 Recommended for high speed circuit protection of electronic equipment such as inverters. Tinplated copper bus and stainless steel hardware. 3/ 8" (M10) stud terminals. Clear insulation cover with breakouts allow cable access from all directions. Maximum ratings: 160 Volts DC. CLASS T FUSE BLOCK Item# Amps Fuse Size List 661-5502 225-400 Class T 7.0'' x 2.3'' 98.49 EA Item# Amps Stud Size List 661-5007100 110-200A 1/ 4"-20 (M6) Up to 4/ 0 AWG 127.99 EA 661-5502100 225-400A 5/ 16"-18 (M8) Up to 4/ 0 AWG 142.49 EA Opt. Accy. Amps Size Fuse List 661-5117 225A 2.75''L x 1.31''W JJN 83.89 EA 661-5118 250A 2.75''L x 1.31''W JJN 83.89 EA 661-5119 300A 2.75''L x 1.31''W JJN 83.89 EA 661-5120 350A 2.75''L x 1.31''W JJN 83.89 EA 661-5121 400A 2.75''L x 1.31''W JJN 83.89 EA • Four stud design for ample access • Insulating cover satisfies ABYC/USCG requirements • Cover breakouts allow wire access in any direction • Stud design ensures secure fuse mounting • Stainless steel studs provide resistance to corrosion • Safe & secure one-piece stainless flange nuts • UL 94-V0 base resists high heat Allows the use of Class T fuses for fast acting circuit protection of inverters and other electronics. CLASS T FUSE BLOCK WITH INSULATING COVER 5007100 5502100 Item# Amps Size List 661-5006100 80A 14 - 4 AWG 58.49 EA • Snap-on terminal cover insulates all conductive parts, satisfying ABYC/USCG requirements • Cover breakouts allow wires from sides or bottom • Terminal screws compress fuse blades within blocks for low resistance connections • Label recess accepts large format label • Fuses sold separately MAXI FUSE BLOCK Item# Description Fuse Stud Size List 661-5191 Battery Terminal Mt. 1 M8 (5/16"-18) 3/ 8" 45.29 EA 661-2151 Battery Terminal Mt. 2 M8 (5/16"-18) 3/ 8" 66.19 EA • Compact, high-amp fuse, appropriate for DC main, inverter, windlass, and bow thruster • Provides high current protection • Weatherproof - for small open boats and other harsh environments • Mounts to 3/ 8" battery post, battery switch, or bus system • Voltage Max. Operating: 58V DC • Amperage Max. Operating: 300A • Terminal Fuses Available: 30–300 Amps • Fuse sold separately BATTERY TERMINAL FUSE BLOCK
RkJQdWJsaXNoZXIy MTI2MTky