GENERAL BOATING WATERSPORTS & BOATS SEATING COVERS/TOPS MAINTENANCE ELECTRICAL HARDWARE PLUMBING PROPS & ANODES FUEL ELECTRONICS & NAVIGATION SAFETY TROLLING & FISHING ANCHORING/ MOORING TRAILERING PAINT VENTILATION FASTENERS STEERING ENGINE ITEM NUMBERS IN RED ARE HAZARDOUS ITEMS IN BLUE ARE NEW ] SEA VALUE v OVERSIZED dCOURIER SURCHARGE SECTION 743 ELECTRICAL Item# Amps Volts Case List 50-11479 30 42V 4 77.69 EA 50-11481 40 42V 4 77.69 EA 50-11483 50 42V 4 77.69 EA 50-11484 60 42V 4 77.69 EA • Waterproof – sealed for engine compartment and bilge area applications • One-push manual trip button allows users to quickly disable circuit • Unique reset mechanism visibly displays tripped condition • Ignition protection PANEL 285 SERIES SURFACE MOUNT CIRCUIT BREAKER Item# Amps Color List 69-CBS30DP 30 Black 119.19 EA Double pole, magnetic-hydraulic, trip free circuit breaker. IEG MAGNETIC CiRCUIT BREAKER Item# Amps Volts Case List 661-7151 10 28VDC Max 5 15.49 EA 661-7152 15 28VDC Max 5 15.49 EA 661-7153 20 28VDC Max 5 15.49 EA 661-7154 25 28VDC Max 5 15.49 EA 661-7155 30 28VDC Max 5 15.49 EA 661-7156 40 28VDC Max 5 15.49 EA 661-7157 50 28VDC Max 5 15.49 EA • Corrosion resistant materials to withstand harsh environments • IP64 water resistant boot protects against dust and splashing water • Push-to-reset operation only disconnects when tripped • Stainless steel lock nuts for secure connections • Red insulating boot included SHORT STOP DC CIRCUIT BREAKER Item# Amps Color List 661-7200 5 Black 36.89 EA 661-7204 10 Black 36.89 EA 661-7208 15 Black 36.89 EA 661-7212 20 Black 36.89 EA 661-7216 25 Black 36.89 EA 661-7220 30 Black 36.89 EA 661-7224 40 Black 36.89 EA 661-7228 50 Black 36.89 EA 661-7202 5 White 36.89 EA 661-7299 8 White 36.89 EA 661-7206 10 White 36.89 EA 661-7210 15 White 36.89 EA 661-7214 20 White 36.89 EA 661-7218 25 White 36.89 EA 661-7222 30 White 36.89 EA 661-7226 40 White 36.89 EA 661-7230 50 White 36.89 EA 661-7205 10 Red 36.89 EA 661-7209 15 Red 36.89 EA 661-7217 25 Red 36.89 EA 661-7221 30 Red 36.89 EA 661-7225 40 Red 36.89 EA 661-7229 50 Red 36.89 EA Red Toggle Black Toggle White Toggle Single pole, magnetichydraulic, trip free circuit breakers. Combines switching and circuit protection into a single device. Rated for 65 Volts DC and 250 Volts AC. Includes mounting screws. A-SERIES SINGLE POLE AC/DC CIRCUIT BREAKER Item# Amps Color List 661-7234 15 Black 75.79 EA 661-7236 20 Black 75.79 EA 661-7237 30 Black 84.79 EA 661-7241 50 Black 75.79 EA 661-7233 10 White 84.79 EA 661-7235 15 White 84.79 EA 661-7260 20 White 84.79 EA 661-7238 30 White 84.79 EA 661-7242 50 White 84.79 EA Black Toggle White Toggle Double pole, magnetic-hydraulic, trip free circuit breakers. Combines switching and circuit protection into a single device. Allows for the neutral circuit on one pole and hot circuit on other pole. Both poles will trip if either pole trips. Rated for 250 Volts AC and 65 Volts DC. Includes mounting screws. A-SERIES DOUBLE POLE AC/DC CIRCUIT BREAKER • Circuit breaker type: Magnetic Hydraulic–trip free • Maximum Voltage: 240 Volts AC, 32 Volts DC • Rated Switch Cycles: 10,000 @ rated amperage and voltage Rocker actuator is flush in the “ON" position, eliminating the risk of accidental switching. “Trip Free" design cannot be held “ON" during fault current condition. Prevents accidental switching of 24 hour circuits. Colored actuator indicates “OFF" position. A-SERIES FLAT ROCKER CIRCUIT BREAKER Item# Type Description Amps List Single Pole 661-7400 Flat Single Pole 5 41.59 EA 661-7402 Flat Single Pole 10 41.59 EA 661-7403 Flat Single Pole 15 46.89 EA 661-7404 Flat Single Pole 20 46.89 EA 661-7406 Flat Single Pole 30 41.59 EA Provides overcurrent protection for inverters, bow thrusters, and windlasses. Combines switching and circuit protection into a single device. "Trip Free" - cannot be held closed after trip. Double and triple pole circuit breakers will trip all poles if any one pole trips. White. DC Features • Large frame provides stud termination for 5-300 Amp loads • Provides overcurrent protection for inverters, bow thrusters, and windlasses • Offers high interrupt capacity - suitable for Main circuit protection • Trip Free - cannot be held closed after trip AC Features • Frequently used for 120 / 240 Volt AC circuit protection • Double pole can be used as AC Main circuit breaker to switch hot and neutral or two hots in 120 / 240 Volt AC Branch applications • Triple pole can be used as 120 / 240 Volt AC Main circuit breaker to switch both lines (hots) and neutral • Double and triple pole circuit breakers will trip all poles if any one pole trips Item# Type Amps List 661-7352 Single Pole 15 61.39 EA 661-7354 Single Pole 25 61.39 EA 661-7355 Single Pole 30 69.19 EA 661-7244 Single Pole 50 69.19 EA 661-7246 Single Pole 60 69.19 EA 661-7248 Single Pole 80 69.19 EA 661-7250 Single Pole 100 69.19 EA 661-7254 Double Pole 60 162.69 EA 661-7267 Double Pole 150 216.19 EA 661-7269 Double Pole 200 216.19 EA 661-7288 Triple Pole 60 210.49 EA 661-7270 Triple Pole 250 279.69 EA Triple Pole Single Pole Double Pole C-SERIES TOGGLE CIRCUIT BREAKER
RkJQdWJsaXNoZXIy MTI2MTky