GENERAL BOATING WATERSPORTS & BOATS SEATING COVERS/TOPS MAINTENANCE ELECTRICAL HARDWARE PLUMBING PROPS & ANODES FUEL ELECTRONICS & NAVIGATION SAFETY TROLLING & FISHING ANCHORING/ MOORING TRAILERING PAINT VENTILATION FASTENERS STEERING ENGINE ITEMS ARE STOCKED IN OUR WAREHOUSES BASED ON REGIONAL DEMAND. IF AN ITEM IS NOT IN STOCK AT A LOCAL WAREHOUSE, ADDITIONAL CHARGES MAY APPLY. 766 SECTION ELECTRICAL Item# Amps Mount List 661-7036 30 Panel 184.21 EA 661-7038 40 Panel 184.21 EA 661-7039 50 Panel 184.21 EA 661-7040 60 Panel 166.48 EA 661-7042 80 Panel 184.21 EA 661-7044 100 Panel 184.21 EA 661-7046 120 Panel 184.21 EA 661-7048 150 Panel 184.21 EA 661-7049 200 Panel 241.27 EA 661-7135 25 Surface 184.21 EA 661-7136 30 Surface 184.21 EA 661-7138 40 Surface 184.21 EA 661-7139 50 Surface 184.21 EA 661-7140 60 Surface 184.21 EA 661-7141 70 Surface 184.21 EA 661-7142 80 Surface 184.21 EA 661-7143 90 Surface 184.21 EA 661-7144 100 Surface 184.21 EA 661-7146 120 Surface 184.21 EA 661-7148 150 Surface 182.75 EA 661-7149 200 Surface 241.27 EA Heavy duty circuit protection when switching and circuit protection are both required. Single lever operation is clearly visible. Ignition protected (conforming to SAE J1171), safe for installation aboard gas-powered boats. Weather resistant. 5/16-18 terminal studs. Maximum voltage 42 volts DC. 187 SERIES THERMAL CIRCUIT BREAKER Panel Mount Surface Mount Use a manually resettable circuit breaker instead of an ATO or ATC fuse. • Drop in replacement for ATO and ATC blade style fuses • Manual push button reset complies with ABYC circuit protection requirements • Compatible with Water-Resistant ST-Blade Fuse Block with cover secured • Compatible with all other ST-Blade Fuse blocks without cover Item# Amps Volts Color Qty List 661-7062 5 12/24V Light Brown 2 18.45 EA 661-7063 7.5 12/24V Brown 2 18.45 EA 661-7064 10 12/24V Red 2 18.45 EA 661-7065 15 12/24V Blue 2 18.45 EA 661-7066 20 12/24V Yellow 2 18.45 EA 661-7067 25 12/24V White 2 18.45 EA 661-7068 30 12/24V Green 2 18.45 EA ATO/ATC-STYLE LOW PROFILE CIRCUIT BREAKER 30A 25A 20A 15A 10A 5A 7.5A Item# Type Description Amps List 661-3102100 2 pole ELCI Main A-Series 120V AC per pole Flat Rocker 30 607.54 EA 661-3103 2 pole ELCI Main C-Series 120V AC per pole Flat Rocker 50 838.09 EA 661-3104 3 pole ELCI Main C-Series 120/240V AC per pole Flat Rocker 50 936.69 EA Residual Current Devices (RCDs) respond to leakage of electrical current outside of the intended circuit path. When the RCD function is combined with a circuit breaker for over current protection, the device is often referred to as an RCBO. In the USA, a device that trips on leakages of nominally 5mA and meets certain standards is called a Ground Fault Circuit Interrupter (GFCI). A device meeting the same standards but with a trip level of 30mA is called an Equipment Leakage Circuit Interrupter (ELCI). These devices provide GFCI Branch or ELCI Main functions and circuit protection in panel mounted breakers. For installation in a power distribution panel. Trips on short circuit, overload, or leakage to ground GFCI Branch – Provides overcurrent and leakage protection per ABYC E-11 for head, galley, machinery and weather deck receptacles ELCI Main – Provides overcurrent and leakage protection per ABYC E-11 for whole boat shore power protection Specifications • Interrupting Capacity: 5,000A • Temperature Min. Operating: -35°C • Temperature Max. Operating: 66°C • Switching Cycles: 10,000 @ rated amperage and voltage • Type Magnetic Hydraulic: Trip free • Mounting Screw: #6-32 Stainless Steel • Mounting Screw Torque: 6–8 in-lb Recommended Regulatory • 3100 – UL 1077, UL 943 Class A • 3103, 3104, 3102100, 3106100, 3091, 3092, 3093 – UL 1077, UL 943 Class A, UL 1500 • AC and AC/DC Circuit Breakers Only – CE marked * 230V AC, Typical of Europe RESIDUAL CURRENT CIRCUIT BREAKER Item# Qty List 661-8035 66 4.06 PK Fits all single- and double-pole A-, B and C-Series circuit breakers 6-32 x 1/ 4" Flat Head CIRCUIT BREAKER MOUNTING SCREW Item# List 661-4100 9.69 EA Protects circuit breakers from being accidentally switched on or off. Fits all single-pole A and B series breakers. Works on any brand breaker panel using standard A or B series circuit breakers. Includes mounting screws. TOGGLE GUARD Item# Amps Volts Pkg. List 12-3005520BP 20 12 Retail 22.73 EA 12-3005530BP 30 12 Retail 22.83 EA 12-3005540BP 40 12 Retail 21.90 EA 12-3005550BP 50 12 Retail 24.30 EA Internal mounting bracket. Overall size 2" x 25/ 32" x 13/ 8". For 6, 12 and 24 volt applications. Complete with two #10-32 stud terminals, and keps nuts. Blister packed. CIRCUIT BREAKER Constructed of molded Bakelite with stamped brass contacts. Protects electrical circuit from damage caused by excess current. These push-to-reset circuit breakers are an economical alternative to magnetic breakers. Quick connect terminal style breakers are vibration and shock resistant. Resettable after tripping. Panel mounted compact design. 4-35A @ 125-250VAC. 32VDC. THERMAL PUSH BUTTON RESET-ONLY AC/DC CIRCUIT BREAKER Item# Amps A B C D List 354-4208101 10 13/ 8" 7/ 16" 11/ 4" 9/ 16" 8.75 EA 354-4208151 15 13/ 8" 7/ 16" 11/ 4" 9/ 16" 8.83 EA 354-4208201 20 13/ 8" 7/ 16" 11/ 4" 9/ 16" 8.83 EA 354-4208301 30 13/ 8" 7/ 16" 11/ 4" 9/ 16" 9.70 EA
RkJQdWJsaXNoZXIy MTI2MTky