GENERAL BOATING WATERSPORTS & BOATS SEATING COVERS/TOPS MAINTENANCE ELECTRICAL HARDWARE PLUMBING PROPS & ANODES FUEL ELECTRONICS & NAVIGATION SAFETY TROLLING & FISHING ANCHORING/ MOORING TRAILERING PAINT VENTILATION FASTENERS STEERING ENGINE ITEM NUMBERS IN RED ARE HAZARDOUS ITEMS IN BLUE ARE NEW D SEA VALUE Y OVERSIZED GCOURIER SURCHARGE SECTION 939 PLUMBING These submersible pumps feature a tough, high-density nylon housing and heavy duty, water cooled, removable motor cartridge for excellent reliability and easy servicing. The dual port fitting allows for easy washdown pump connection. Patented anti-airlock feature allows the pump to clear trapped air. Ignition protected w/6' wire. 2-year warranty. PIRANHA DUAL PORT LIVEWELL PUMP Item# GPH Inlet Outlet Volts Amps List 275-35711310 800 3/ 4" 3/ 4" 12 4.5 137.90 EA 275-35710310 1100 3/ 4" 11/ 8" 12 4.5 152.71 EA Repl. Parts Description List 275-9462000 Repl. Cartridge 113.07 EA Item# GPH For Inlet Outlet Volts List 275-1700011030 800 40 Gal Tanks 3/ 4" 3/ 4" 12 272.99 EA This unique pump eliminates a physical connection between the motor and the impeller and turns the impeller with a magnetic drive. If the pump is dry or the impeller is clogged, the motor can run dry without damage. Patented anti-airlock feature allows the pump to clear trapped air. Includes a dual port for easy washdown pump connection. Ignition protected. 3-year warranty. "BAIT SENTRY" DUAL PORT LIVEWELL PUMP Fishbox Discharge Pumps • No filter required • Dry running capability • Connections for 38mm (11/ 2") ports • Up to 19 lpm (5 US gpm) flow • Meets ISO 8846 MARINE and USCG Regulations for Ignition Protection • Meets BSEN 50081 (Electro Magnetic Compatibility) Perfect for emptying a fishbox after fishing. Self-priming pump is designed for passing typical debris, such as bait residue, particles of ice, fish scales, etc. Its dryrunning capabilities and the 360º rotatable head allow this pump to be mounted in almost any position for total flexibility. FISH BOX EVACUATION PUMP Item# GPM Ports Volts Amps List 6-509001000 5 11/ 2" 12 10 726.35 EA Item# GPM Ports Volts List 698-BP4772 4.2 Inlet: 1 1/ 2"; Outlet: 1" 12 379.46 EA The Gulper Grouper MK3 boasts 90° port orientation for direct replacement of existing macerator pumps in compact areas. Unlike macerator pumps, non-choke Gulper valve technology means no filters, and no clogged impellers with associated motor burn out. Pump is equally dependable for bait box evacuation or for pumping toilet waste. Equipped with 360° head rotation, makes lining up hose connections a cinch. Easy to clean and maintain. GULPER GROUPER MK3 FISHBOX/WASTE DISCHARGE PUMP Item# GPM Hose Volts Amps List 698-BP4572 6.5 1" or 11/ 2" 12 7 492.34 EA This heavy-duty, single diaphragm pump can run dry without damage and has no impeller to clog or burn. Ideal for fishbox waste to replace a macerator pump. 360° Head rotation for easy installation. Non-choke valves and easy maintenance. GULPER GROUPER FISHBOX EVACUATION PUMP Livewell Valves Item# Description List 81-MPV11FN01 Quick Lock connection 52.04 EA 81-MPV01FN01 Barbed Connection 51.10 EA The V1 valve provides remote drain control and eliminates the need for drain plugs and standpipes. Features dual seals for positive shut-off in the "CLOSED" position and a straight unrestricted flow path in the "OPEN" position. This valve is non-directional. Remote drain control for any boat's livewell, baitwell or cooler. Provides OPEN / CLOSED modes. V1 - 2 POSITION SHUT OFF VALVE Item# Description List 81-MPV03FN01 Front cable approach 67.27 EA 81-MPV03RN01 Rear cable approach 67.27 EA A reversible check valve that allows one pump to perform the basic livewell functions necessary to keep your catch alive in a passive or automatic manner. It also has a third closed "RECIRC" position. In the "AUTO" position, the pump will recirculate and aerate the livewell water and and blend in a portion of fresh water. Used water is expelled out the overflow to prevent ammonia build up. When on plane, the valve's check flap prevents water loss, but continues recirculation. Water lost while running is automatically made up when the boat is brought off plane. When outside water is not wanted or available, such as adding ice, livewell additives, etc., place the valve in the "RECIRC" position. Used for Automatic drain control and livewell management. • Accepts mounting of one standard aerator pump for both filling and recirculation • Provides RECIRC / EMPTY / AUTO modes V3 - 3 POSITION AUTOMATIC VALVE Item# Description List 81-MPV04FN01 Front cable approach 67.27 EA 81-MPV04RN01 Rear cable approach 67.27 EA Allows one aerator pump to be mounted directly to the valve body for both filling and recirculation duties. In the "FILL" position, the valve will close the livewell drain side of the valve so the pump has access to outside water. Once full, place the valve in the "RECIRC" position to close the drain and allow full recirculation. Occasionally returning to the "FILL" position will keep the livewell topped off and freshened. The "EMPTY" position allows gravity draining. Any additional fill or recirculation pump is only optional as a backup. When in "AUTO" with the pump on, all livewell functions are handled. Ideal in walleye boats or other high profile boats for drain control and livewell management. Provides FILL / EMPTY / RECIRC modes. V4 - 3 POSITION SELECT VALVE Item# Description List 81-MPC103100 Recirc/Empty/Auto. Use with V3 Series valves 58.41 EA 81-MPC104100 Fill/Empty/Recirc. Use with V4 Series valves 59.35 EA MPC103100 MPC104100 ACTUATORS FOR V SERIES
RkJQdWJsaXNoZXIy MTI2MTky